10.7 Set up function
Standby state (screen display OFF), long
press " "until the screen" OFF "disappear
jump into the parameter setting state, "
"through " ", to control the addition and
subtraction operation, set the state of light
point" " switch the next setting, parameter
switch round, from the first parameter cycle
again.
*" Setup function "is recommended to be operated
under the guidance of professionals and not to be
adjusted privately (see maintenance page for page
14);
11.Ice-Making Workflow
11.1.The display is all on after power-on, and all
off after 1 second. Then enter the power-on balance
state. The hot valve opens, and the water valve and
fan are controlled. After 30 seconds, the press
opens, and after another 5 seconds, the hot valve
closes to start ice making.
11.2.During the ice making process. The
compressor continues to open, the hot valve and the
drain valve are closed, the fan is controlled, the
water pump opens after 30 seconds, the water valve
is controlled within the first 5 minutes, and it
is forced to close after 5 minutes. When the time
exceeds 23 minutes or it is detected that the water
temperature is lower than 3°C, the set ice-making
time will be delayed. When the delay time expires,
the ice-making ends. If water is needed, open the
drain valve 30 seconds before the end of ice
making.
11.3 After the ice making is over, it enters
the deicing state. The compressor continues to
open, the hot valve opens, the water valve is
controlled, and the water pump, fan and drain valve
are closed. The maximum time for deicing is limited
to 6 minutes. If the ice does not come off in 5
minutes, turn on the water pump for 1 minute. If
the ice is still not removed, switch to ice making.
Three times in a row for more than 6 minutes, switch
to de-icing overtime shutdown.
11.4 After the ice is taken off, if the ice in
the storage refrigerator is not full, it will enter
the ice making state and start a new cycle. If the
refrigerator is full of ice, it will enter the full
ice-full shutdown state. The water pump,
compressor, hot valve, water supply valve, fan and
drain valve are all closed. If the ice is taken away,
the ice full indicator will flash within 180
seconds after the ice is full. After the ice is full
for 180 seconds, turn on the power and start a new
cycle. If the ice is not taken away, it will always
be full of ice.
12.Operation Inspection
Make sure the water inlet tap is turned on
Confirm that the water inlet valve has been
opened
The ice machine is powered on
Check all water pipes and pipe joints to ensure
that there are no leaks
13. Routine cleaning
Clean environment: clean the surroundings of the
ice machine frequently to keep the environment
clean and make the equipment operate efficiently。
Shell cleaning: Use a sponge dipped in neutral
cleaning fluid to clean the ice machine and dry it
with a clean soft cloth. Stainless steel cleaner
can be used when necessary.
Air filter cleaning: The filter can filter out
dirt or dust in the air and prevent the condenser
from clogging. If the filter is clogged, the
performance of the ice maker will decrease. It is