Page 20 of 62
- “YLOST” – Y needs to go home.
- “XSWITCH” – possible problem with home switch.
- “YSWITCH” – possible problem with home switch.
Press key number 1 will return to “Vend Mechanism” if all vend mech Error Codes have not been cleared. If all
vend mech Error Codes have been cleared the next error mode will be displayed, or “No Error Codes” if there
are no Error Codes. Press key number 1 will return to “Error Codes”.
“Control System” - Control System Summary Error Codes
Press key number 4 and the display will show one of the following:
- “Door Switch”, indicating a door switch in the open position for more than 1 hour.
- “RAM Checksum”, indicating the check sum for service mode settings memory has been corrupted.
- “Scale Factor”, indicating a peripheral has introduced a scaling factor that is incompatible with current
setting.
- “FRAM”, memory module read/write error.
- “RTC”, RTC read/write error, real time clock issue.
- ‘Low Battery”, low battery issue.
- “PWROUT”, power lost.
- “FCTRY TST”, VMC was not tested at the manufacturer.
Press key number 1 will return to “Control System” if all control system Error Codes have not been cleared. If all
control system Error Codes have been cleared the next error code will be displayed, or “No Error Codes” if there are
no Error Codes. Press key number 1 will return to “Error Codes”.
“CHANGER” - Changer Summary Error Codes
Press key number 4 and the display will show one of the following:
- “Changer Comm”, indicating a changer communication error (No communication for more than 2
seconds).
- “Tube Sense”, indicating a tube sensor error.
- “Changer Inlet”, indicating an inlet chute blocked error (no coins sensed in acceptor for 96 hours).
- “Tube Jam #”, indicating a tube jam error.
- “Changer ROM”, indicating a changer ROM check sum error (failed changer).
- “Excessive Escrow”, indicating excessive escrow attempts (more than 255 since last coin sensed).
- “Coin Jam”, indicating a coin jam reported by coin mech.
- “Low Acceptance”, indicating a low coin acceptance rate (less than 80%).
- “Acceptor Disconnected”, indicating an acceptor is unplugged.
- “Coin Routing Err”, indicating a coin was miss-routed.
Press key number 1 will return to “CHANGER” if all changer Error Codes have not been cleared.
If all changer Error Codes have been cleared the next error code will be displayed or “No Error Codes” if there are
no Error Codes. Press key number 1 will return to “Error Codes”.
“Bill Validator” - Bill Validator Summary Error Codes
Press key number 4 and the display will show one of the following:
- “Bill Val Comm” indicating a bill validator communication error (No communication for more than 5 seconds).
- “Bill Stack Full” indicating the bill stacker is full.
- “Bill Motor Error” indicating a defective motor in the validator.
- “Bill Jam ” indicating a bill jam in the validator.
- “Bill Val ROM” indicating a check sum error.
- “Bill Stack Open” indicating an open stacker.
- “Bill Sense Err” indicating a bill validator sensor error.