COMPRESSOR WILL NOT START
Defective starting
component
(capacitor, relay).
Close Service Door.
Check Harness from Compressor to AC
Distribution Box.
Compressor will not
start.
Service Door is
open.
Compressor is
unplugged.
Replace Service Door Switch.
Defective Door
Switch.
Check power source at outlet.
Replace Encapsulated Temp. Sensor.
Low voltage.
Defective
Encapsulated
Temp. Sensor.
In Relay Test, test that the Compressor
will turn on.
Test in
Programming Test
Mode.
R134a - Replace starting component.
R290 Replace the refrigeration deck
and return it to Crane
Defective
Compressor.
Defective Cabinet
Control Environmental
Board in AC Distribution
Box.
R134a-Replace Compressor.
R290 Replace the Refrigeration Deck
and return it to Crane
Replace Cabinet Control Environmental
Board.