13
How to Read Trouble Messages
Any failure or abnormal events that may occur are indicated by trouble messages, and the
Trouble indicator is lit. Press <MEMORY> to read out messages and other events stored in
memory.
How to Display Events from Memory
The system memory stores the last events. Press <MEMORY> to display list of events.
Following the display of current system alarms the panel will then sequence through
the 127 historical memory events starting at the most recent event. The second table
shows the alarm events that can be displayed in memory mode and what indicators are
used to show them.
The system will display the last event and automatically scroll to the next one every 2.5
seconds, and a beep is emitted. Use the arrow keys to scroll up manually.
Wait until all messages are displayed, or press <ENTER> to cancel memory readout.
EVENT TYPE
DEVICE INDICATOR STATUS
ACTIVATION Zones 1-8 LED's 1-8 On Steady
BYPASS Zones 1-8 Ready Byp
LED's 1-8
On Steady
On Steady
DETECTOR TAMPER
(SHORT CIRCUIT)
Zones 1-4 Trouble
LED's 1-4
Flashing On
Steady
DETECTOR TAMPER
(OPEN CIRCUIT)
Zones 5-8 Trouble
LED's 5-8
Flashing On
Steady
CABINET TAMPER Cabinet or Satellite
Siren
Trouble Flashing
LOW BATTERY Controller Battery System
LED 1
On Steady
On Steady
MAINS FAILURE Controller Mains
Supply
SYSTEM
LED 2
On Steady
On Steady
RADIO ZONE LOW BATTERY