EasyManua.ls Logo

Crowcon Xgard - Diagram 1: Xgard Type 1 Certification Labels

Crowcon Xgard
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Certification Xgard and Xgard IR
2
Diagram 1: Xgard Type 1 certification labels
Xgard Type 1 Intrinsically Safe gas detectors may be used within hazardous areas with
the following classifications provided a safety barrier is used in accordance with the
instructions provided:
Zones 0, 1 or 2 (ATEX, IECEx and Inmetro certified versions)
Division 1 or 2 (UL certified versions)
1180
Xgard
Gas Detector
Baseefa04ATEX0115X
Ex ia IIC T4 Ga -40ºC
Ta
+55ºC
IECEx BAS05.0042X
STATIC HAZARD
CLEAN ONLY WITH A
DAMP CLOTH
MADE IN UK OX14 4SD
II 1G
1180
Xgard
Gas Detector
Baseefa04ATEX0115X
Ex ia IIC T4 Ga -40ºC
Ta
+55ºC
IECEx BAS05.0042X
MADE IN UK OX14 4SD
II 1G
1. Xgard Type 1 ATEX Nylon 2. Xgard Type 1 ATEX Stainless Steel
3. Xgard Type 1 UL Oxygen 4. Xgard Type 1 UL Toxic
Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +55°C
Xgard Type 1 - ST-ST
UL-BR 15.0042X
Ex ia IIC T4 Ga -40°C ≤ Ta ≤ +55°C
ATENÇÃO - RISCO POTENCIAL DE CARGAS
ELETROSTÁTICAS - VER INSTRUÇÕES
Xgard Type 1 - GFN
UL-BR 15.0042X
5. Xgard Type 1 Inmetro Nylon 6. Xgard Type 1 Inmetro Stainless Steel

Related product manuals