Xgard en Xgard IR
59
Nederlands
Goedkeuringscode Xgard Type 1:
Xgard Types 2,3,5,6,IR:
Xgard Type 4:
ATEX/IECEx/Inmetro:
II 1 G Ex ia IIC T4 Ga
Tamb = -40°C tot 55°C
UL & cUL:
Klasse I, Division 1, Groepen A,B,C,D
ATEX/IECEx/Inmetro:
II 2 GD Ex db IIC T6 Gb
Extb IIIC T80°C Db
Tamb = -40°C tot 50°C
II 2 GD Ex db IIC T4 Gb
Extb IIIC T110°C Db
Tamb = -40°C tot 80°C
UL: Klasse I, Division 1, Groepen B,C,D
ATEX/IECEx/Inmetro:
II 2 GD Ex db IIC T3 Gb
Extb IIIC T180°C Db
Tamb = -40°C tot 150°C
Nr. veiligheidscerticaat. Xgard Type 1:
Xgard Types 2,3,4,5,6,IR:
ATEX: Baseefa04ATEX0115X
IECEx: BAS 05.0042X
Inmetro: UL-BR 15.0042X
ATEX: Baseefa04ATEX0024X
IECEx: BAS 05.0043X
Inmetro: UL-BR 13.0208X
Normen Xgard Type 1:
Xgard Types 2,3,4,5,6,IR:
EN60079-0:2012+A11:2013, EN60079-
11:2012, IEC 60079-0:2011 (Ed 6),
IEC60079-11: 2011 (Ed 6), UL913
EN60079-0:2012+A11:2013, EN60079-
1:2014, EN60079-31:2014, IEC 60079-
0:2011, IEC60079-1: 2014, IEC60079-
31:2013, UL1203 (except Type 4)
EMC EN50270, FCC Part 15, ICES-003