15
24.0V
24.5V
25.0V
25.5V
13
Setting voltage point
back to battery mode
when selectingSBU
priority” or Solar first
in program 01.
Battery fully charged
24V
24.5V
25V
25.5V
26V
26.5V
27V (default)
27.5V
28V
28.5V
29V
16
Charger source priority:
To configure charger
source priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar first
Solar energy will charge battery as first
priority.
Utility will charge battery only when
solar energy is not available.
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar and Utility (default)
Solar energy and utility will charge
battery at the same time.
Only Solar
Solar energy will be the only charger
source no matter utility is available or
not.