How to defeat Brown-out effect protection circuitry on a Crown Amplifier?
- MMaria BrockSep 8, 2025
To defeat the Brown-out effect protection circuitry on your Crown Amplifier, pull TP249 to +15V (TP-6) with a jumper, as shown.
How to defeat Brown-out effect protection circuitry on a Crown Amplifier?
To defeat the Brown-out effect protection circuitry on your Crown Amplifier, pull TP249 to +15V (TP-6) with a jumper, as shown.
What to do if nulls off the error amplifier output of channel 1 on Crown ce 4000 Amplifier?
To null the error amplifier output of channel 1 on your Crown Amplifier, place a jumper between TP100 and TP104 (Jumper 1 in Figure 4.6).
What to do if nulls off the error amplifier output of channel 2 on Crown Amplifier?
To null the error amplifier output of channel 2 on your Crown Amplifier, place a jumper between TP200 and TP204 (Jumper 2 in Figure 4.6).
Channels | 2 |
---|---|
Power Output (8 Ohms Bridged) | 2000W |
Total Harmonic Distortion | < 0.5% |
Input Sensitivity | 1.4V |
Input Impedance | 20 kOhms balanced, 10 kOhms unbalanced |
Power Output (4 Ohms) | 1000W |
Frequency Response | 20Hz - 20kHz |
Protection | Short circuit, thermal, overload |
Provides service information for the Crown CE 4000 amplifier.
Describes the CE 4000 as a professional, compact audio amplifier.
Defines the manual's applicability to all CE 4000 amplifier versions.
Covers basic warranty policies and customer service procedures.
Explains the audio signal's journey through the amplifier's internal circuits.
Details protection circuits, control functions, and indicators like Fault and Clip LEDs.
Describes the power entry, filtering, low-voltage supplies, PFC, and isolation stages.
Outlines a three-step process for effective repair: symptom determination, cause identification, and repair.
Discusses the advantages and disadvantages of Surface Mount Technology (SMT) in amplifier design.
Provides instructions for safely disassembling the amplifier for inspection and service.
Guides on identifying and repairing common amplifier problems based on symptoms and causes.
Lists essential test equipment required for accurate calibration and servicing of the amplifier.
Details electrical tests to verify amplifier operation and performance parameters.
Describes procedures for calibrating specific amplifier functions like filters and sensors.
General guidance on ordering replacement parts from the Crown Parts Department.
Details the process for ordering parts, including required information and payment terms.
Lists mechanical components and assemblies with part numbers and exploded view references.
Lists circuit board part numbers and their corresponding schematic sheet references.