Total Harmonic Distortion (THD) | < 0.05% |
---|---|
Input Sensitivity | 1.4 V |
Signal to Noise Ratio | > 100 dB |
Input Impedance | 20 kOhms |
Voltage Gain | 32 dB |
Power Output (4 Ohms) | 1800W per channel |
Frequency Response | 20 Hz - 20 kHz |
Damping Factor | > 1000 |
Cooling | Forced air |
Power Requirements | 120V |
Warns about locating sensitive equipment near the amplifier due to its strong magnetic field.
Details compliance with FCC rules for radio frequency energy and potential interference.
Highlights key features like Grounded Bridge, ODEP, IOC, and VZ power supplies.
Instructions for unpacking, inspecting for transit damage, and saving packing materials.
Guidance on installing the amplifier in a rack or stacking, ensuring safe operation.
Recommendations for rack mounting and ventilation to maintain optimal operating temperature.
Details on balanced and unbalanced input connector wiring configurations.
Guidelines for choosing speaker wire gauge and connectors based on distance.
Instructions for connecting inputs and outputs in Stereo and Bridge-Mono modes.
Details on wiring the amplifier for Parallel-Mono operation, including jumper wire use.
Guidance on connecting the amplifier to the AC power source and safety precautions.
Step-by-step instructions for safely powering the amplifier on and off.
Important safety and performance precautions to observe during operation.
Explains ODEP for preventing shutdowns and IOC for detecting distortion and faults.
Describes the Grounded Bridge topology and Variable Impedance (VZ) power supply.
Details on PIP-Lite module, input sensitivity, and ground lift switch configurations.
Guaranteed power output ratings for Stereo, Bridge-Mono, and Parallel-Mono modes at various impedances.
Details frequency response, phase response, signal-to-noise ratio, THD, and IMD.
Covers output impedance, voltage gain, AC mains requirements, and input impedance.
Provides physical dimensions, weight, and center of gravity for the amplifier.
Identifies common issues like no power, no sound, or distorted sound and their potential causes.
Procedures for obtaining warranty service outside the US and Canada.
Guidance on seeking service from US authorized centers or directly from the factory.
Detailed steps for returning the unit for factory repair, including SRA and packing.
Details the 3-year warranty period, coverage, and exclusions for new Crown products.
Instructions on how to notify Crown and ship the product for warranty service.
Covers disclaimers for damages, warranty alterations, design changes, and legal remedies.
Specific procedures for obtaining warranty service from local importers outside the US and Canada.