EasyManua.ls Logo

CS THERMOS BRAVA - 14. Alarm Codes

CS THERMOS BRAVA
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
14
14. ALARM CODES
For your own safety do not tamper or modify any of the machine's components: the
manufacturer does not guarantee the normal operation, that as a result may be very dangerous.
In case of malfunctioning, difficulties, or whenever a safety device is activated, it is important to
contact authorised personnel. All operations must take place when the stove is cold and disconnected
from the power supply.
DISPLAY MEANING
Motor flue gas
Non working fumes motor: contact an authorised technician
1 heat.elem.KO One of the resistors is not working: contact an authorised technician
2 heat.elem.KO Both resistors are not working: contact an authorised technician
heat.element KO The resistors are continually supplied with power: contact an authorised technician
gas probe
The fumes temperature probe is interrupted or disconnected: contact an authorised
technician
room probe
The room temperature probe is interrupted or disconnected: contact an authorised
technician
Thermostat gas
Intervention on the part of the fumes discharge safety thermostat clean the inside of
the stove, reset the thermostat and restart the stove
Thermostat auger
Intervention on the part of the fuel auger safety thermostat: clean the inside of the
stove, reset the thermostat and restart the stove
Pressure switch Air pressure regulator is not working: contact an authorised technician
system error Internal error of the electronic control box: turn stove off and restart it
black out Loss of electric power: clean the burner and restart
Failed ignition Failed start-up: clean the burner and restart
Turn off fire Flame turns off while operating: clean the burner and restart
Over heating gas Overheating of combustion fumes: clean the stove completely and restart.
Cont. operation Malfunctioning of pellet loading motor: contact an authorised technician.
service Stove maintenance warning: contact an authorised technician
TO RESTORE STOVE OPERATION KEEP THE KEY PRESSED FOR 3 SECONDS