ENGLISH
END PART OF THE FLUE SYSTEM
The stack must not be installed in spaces that are closed, poorly ventilated or, in general, where smoke can
collect.
It is necessary to check that there are no flammable elements (plants, wood) or elements that could be visually
damaged (walls, windows) within 3m of the flue.
WARNING: Seeing that regulations regarding installation of pellet fuelled stoves are constantly being
updated, ask ones installer for eventual changes.
8. OXIDISING AIR INTAKE
Oxidising air can be taken from the atmosphere as long as there is sufficient ventilation, otherwise it is
necessary to extend the tube of the air intake: in this manner it is possible to guarantee an optimal combustion
without having to open air intakes in the room. For both cases please refer to the installation regulations in
vigour to avoid health risks of those who are in the room where the machine has been installed.
Do not use flexible tubes and place a grid over the entrance (external) of the tube in order to stop alien
elements entering the system which could jeopardise the correct functioning.
MINIMUM DISTANCES FOR THE POSITIONING OF THE AIR INTAKE
For correct and safe positioning of the air intake (see
fig.9) where the minimum distances for any opening
are indicated.
It is important to be aware of other wall discharges of
other machines or kitchen hoods.
Raccordo 80-100
Raccordo a "T"
Ø 80