EasyManuals Logo

Cub Cadet Challenger 700 Operator's Manual

Cub Cadet Challenger 700
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
Periodic Maintenance and Adjustment 8-61
Table 4: Solution of Common Problems in Electrical System
S/N Problems Solutions
1
Lights do not work.
1. Check if the headlight switch functions well.
2. Check if the wires are broken.
3. Check if the lamps or bulbs are burned out or broken.
2
Vehicle cannot go into 4
wheel drive mode.
1. Check if the control switch on meter board works well.
2. Check if the differential lock control magneto plug in rear
reduction gear box is damaged.
3. Check if any wires are broken.
3
Rear differential will not
work.
1.
Check if the control switch on meter board works well.
2.
Check if the differential lock control magneto plug in rear
reduction gear box is broken.
3.
Check if any wires are broken.
4
Meter display is not
normal.
1. Check if the sensor is damaged.
2. Check if the meter is broken.
3. Check if the surface of speed sensor is contaminated with
iron dust.
5
Start switch on meter
board will not work.
1. Check if the switch is broken.
2. Check if any wires are broken.
3. Check if the ECU is broken

Table of Contents

Other manuals for Cub Cadet Challenger 700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cub Cadet Challenger 700 and is the answer not in the manual?

Cub Cadet Challenger 700 Specifications

General IconGeneral
BrandCub Cadet
ModelChallenger 700
CategoryUtility Vehicle
LanguageEnglish

Related product manuals