14-29
14. PERIODIC SERVICE
Sc2400 Operator’s Manual
7. Blow air through the element from the inside out
using 42 to 71 psi (0.29 to 0.49 MPa, 3.0 to 5.0
kgf/cm
2
) compressed air to remove the
particulates. Use the lowest possible air pressure
to remove the dust without damaging the
element.
8. Replace the element with a new one if the
element is damaged, excessively dirty or oily.
9. Clean inside of the air cleaner canister and
canister cover.
10.Reinstall the air cleaner element.
11.Replace the air cleaner canister cover. Make sure
that the rubber dust unloading valve points
downward.
12.For correct installation, follow the instruction
molded onto the canister cover.
13.Hook the two latch hooks onto the air cleaner
canister.
14.Push the top of the latches inward toward the
canister cover to lock the latches and secure the
canister cover.