14-29
14. PERIODIC SERVICE
Sc2400 Operator’s Manual
7. Blow air through the element from the inside out 
using 42 to 71 psi (0.29 to 0.49 MPa, 3.0 to 5.0 
kgf/cm
2
) compressed air to remove the 
particulates. Use the lowest possible air pressure 
to remove the dust without damaging the 
element.
8. Replace the element with a new one if the 
element is damaged, excessively dirty or oily.
9. Clean inside of the air cleaner canister and 
canister cover.
10.Reinstall the air cleaner element.
11.Replace the air cleaner canister cover. Make sure 
that the rubber dust unloading valve points 
downward.
12.For correct installation, follow the instruction 
molded onto the canister cover.
13.Hook the two latch hooks onto the air cleaner 
canister.
14.Push the top of the latches inward toward the 
canister cover to lock the latches and secure the 
canister cover.