46 47
Set Main Zone Area:
TIPS
To restart the One-Time Setup process press and hold 
STOP + Settings + Left arrow together for more than 4 
seconds. This will invoke Factory Defaults 
(out-of-the-box settings).
C. Test Base Station Position  
After setting the area, U001 (“Test 
Base Station Position”) is displayed:
Scroll to select an approximate area  
(EU-m
2
/US-ft
2
) for the Main Zone, where 
the Base Station is installed.
If an additional zone (Sub-Zone or 
Separated Zone) exists, do not include it in 
main zone’s area (it will be set separately).
Place the mower on the 
lawn, 3 m (10 ft) in front 
of the entrance to the 
Base Station, facing the 
Perimeter Wire, and press 
OK to start the test. 
• 
If the  E3  (“No wire signal”) message is displayed, check that 
the Power Supply, power cord and Base Station wires are all 
connected properly. Check for possible Perimeter Wire cuts.
• 
If the UO51 (“Reposition Base Station”) message is 
displayed, check that the Base Station is aligned with the 
Perimeter Wire. Move any obstacles preventing entry into 
the Base Station.
•  Be careful not to damage irrigation pipes when 
hammering down the stakes.
Insert the remaining two stakes into 
the Base Station. Press OK.
The mower will drive to the Base Station 
and enter it.
Next, it will drive out and wait in front of 
the Base Station and display U002 (“Peg 
Base”).