01021076
Low Battery Battery needs replacement. Replace with Panasonic Model# CR 2032 3V battery
Low Salt Level
Salt level is low; less than 15 days of
salt remaining.
Contact Culligan dealer for salt delivery or fill brine
tank with salt.
Motor Home Err
The controller failed to detect proper
position sensor feed back during INI-
TIALIZATION (not during a regen or
progressive flow)
Verify that the proper valve type was selected in First
Time Setup. Check connections of motor and position
sensors at both the motor and the GBE board.
No Refill
Failure to refill brine tank. Refill re-
strictor plugged.
Air in brine line cause float to slam
shut.
Clean or replace refill restrictor.
Verify all tubing connections are properly assembled.
No Remote
Signal
Main board is not receiving a signal
from the remote.
Remote is off, out of range or on a different channel
from the main board. If interference is suspected, try
moving the remote closer or switching to a different
channel on both the main and remote units
Pos Sensor Err/
Motor Position
Error
The controller is seeking a known
valve position before/during/after a
regen, or during progressive flow, but
cannot find it (this error does NOT
appear during initialization).
Check connections of motor and position sensors at
both the motor and GBE board.
Replace Ext Filt
Total gallons through the secondary
filter (i.e. “Big Blue” filter) has ex-
ceeded the specified capacity of the
Big Blue.
Replace optional filter cartridge. Reset the external fil-
ter media life at Main Menu/ Accessories/ Ext. Filter
menu
Salt Bridging
Brine tank has low concentration of
brine, but solid salt exists above the
liquid brine level.
Use a tool to break up any salt bridge inside the brine
tank