10
Stage 2
GRP edge trims
ThefollowingpagesincludeinstructionsforxingthemostcommontypesofGRPedgetrims.Foracomprehensivelistoftrimapplicationssee
the trim application pages of this manual. All trims are supplied in 3m lengths as standard with the exception of F300. Heavy duty trims are
available by special order.
EdgetrimsaremanufacturedinGRP.Onesidehasahighadhesionnish(mattnish),theothersidehasaglossynish,alwaysbondtothe
mattnish.
Alltrimsmustbexedwithnailsorstaplestothedeckingboard.
WiththeexceptionoftheF300FlatashingandtheD260Anglellet,thetrimsmustbebondedinplaceusingthetrimadhesive.Silicone
sealantorgeneral-purposemasticsarenotsuitableadhesivesforthexingoftrims.
Cure It Trim Adhesive
CureItTrimAdhesiveisappliedwithaskeletonguntothebattensaroundtheperimeteroftheroof.Acontinuousbeadissufcienttoholdthe
trims in place. The trims should be ‘rubbed’ into place to ensure good bonding.
Joining Trims
Trims are either nailed to the decking boards using a 13mm galvanised clout nail or stapled in place with a gas powered or compressed air
stapler.Holdthetriminplaceensuringthefaceisvertical.Drivexingsinateachend,thenthemiddleandthenat100mmcentresthereafter.
Most common trim types and application instructions:
A170/A200/A250 - Drip Trim
TheAtypetrimisadriptrim,ttedtothelowestedgeoftheroofusuallywheretherainwater
owsintothegutter.Twosupportbattensshouldbexedtotheperimeteroftheroofto
providespacefortheguttertotbehindthetrim,withtheouterbattenattached10mmlower
thantheinnerbattentoallowthetrimtositushwiththeroof.Applyadhesivetothebatten
in a continuous strip then rub the trim into place and nail to the decking. Do not nail through
the front of the trim. If the pitch of the roof is only minimal, rainwater is likely to hold behind
the trim. A planing machine can be used to take 2mm off the deck to allow the trim to lay
ushwiththeboard.
TRIM DETAILS: A170: This is designed for applications where it is not possible to use the
larger A200. A200: This is the standard size drip trim. A250: This drip trim is ideally suited for
use on warm roofs.
Decking GRP Layer and bandage
Support batten
Brick
Fascia
Gutter
A170
Trim adhesive
A170/200/250 Application diagrams:
NOTE: If the fall of the roof is only slight, the end of the
decking board should be planed by 2mm before the battens
areattached,toallowthetrimtositushwiththerestof
the roof.