4 — PROGRAMMABLE PARAMETERS
Curtis AC F4-A Motor Controller – August 2020 Return to TOC
pg. 34
Speed Mode Express Parameter menus
Speed Mode Express is a simplied version of Speed Mode with a reduced set of parameters that is
adequate for most speed-controlled applications. Speed Mode Express oers a less complex setup
when multiple modes are employed (i.e., dierent maximum speeds, acceleration rates, or braking
rates based upon vehicle operating conditions).
Note: e Curtis Integrated Toolkit
TM
Programmer App does not lockout the Speed Mode parameters.
To prevent conicts, follow the images here, paying attention to the parameter’s VCL name where:
Speed Mode Express parameters end in “_SpdMx
Speed Mode parameters end in “_SpdM”.
e six basic Speed Mode Express parameters whose VCL Parameter_Names end with “_SpdMx
cannot be substituted with the similar Speed Mode parameters which end in “_SpdM” in VCL
programs. Always use the VCL parameter name as shown in the Curtis Integrated Toolkit
TM
control
mode selection.
SPEED MODE EXPRESS.............................. p.40
SPEED CONTROLLER.................... p.40
— Max Speed
— Kp
— Ki
— RESPONSE................................... p.40
— Accel Rate
— Decel Rate
— Brake Rate

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis Instruments F Series and is the answer not in the manual?

Curtis Instruments F Series Specifications

General IconGeneral
BrandCurtis Instruments
ModelF Series
CategoryController
LanguageEnglish

Related product manuals