12
3.PROG/SET:FUNC switch:
In display mode,PROG/SET key and screen shows Cd00
(General parameter input area).,Press PROG key again
and screen shows CE-00 (failure and engineering mode). If
pressed PROG key now, screen would return to display
mode.
SAVE function: In parameter input mode, press PROG/SET key will save
new parameter just input.
4.READ:READ function:When display shows Cd-?? (General parameter Input mode) or
CE-?? (Failure display and engineering mode), Press
READ to parameter input mode. Screen showing
previously parameter setting. Change of parameter can be
proceeding.
Back to display function:Press READ at parameter input mode can escape
from parameter input mode and not save new parameter.
5.
Key (< as shown): SHIFT function:press < key to swich position of nonius,
when the nonius is at left,press <key nonius will be back to
right,when accommodate to press ▼、▲key to modify
parameter in this mode.
6.▼、▲ key:
Item of display changing:Press▲, ▼ key at display mode, select required
item.
Parameter selection:Press ▲,▼ key to change value when screen
shows Cd- (General parameter input area) or CE-
(Failure display and engineering mode). Press and
hold ▲,▼ key can progressively increase or
decrease value.
Parameter modification:Press ▲,▼ key at parameter input mode can
change parameter. Using with SET key to