Motor vibration compensation (Settable range100
500)
The function cannot be modified during revolution.
This function is being modified vibration when the motor spin out,
set
Cd03=0
When the motor vibrates and know the value of vibration by Cd02=10
E.g.: cause Cd02=10 indicate 160
210
assume Cd68 = 200
§
Cd69
Motor speed search time(Settable range 0
15)
The function cannot be modified during revolution.
Adding Function CD28
§
Cd70
Dynamic Braking active level (Settable range 120~140)
This function cannot be modified during revolution
This function is to adjust active point of dynamic braking.
Note:
220V series: protection point voltage (VDC)= Cd70
×
200V
×
%
×√
2
400V series: protection point voltage (VDC)= Cd70
×
400V
×
%
×√
2
§
Cd71
Over Voltage prevention function active point (Settable range 130~150)
This function cannot be modified during revolution
This is to adjust the over voltage protection active point when over voltage occurred.
Note
220Vseries
active voltage (VDC)= setting value
×
200V
×
%
×√
2
400Vseries
active voltage (VDC)= setting value
×
400V
×
%
×√
2
§
Cd79
Auto saving function setting (setting range 0~1)
This function can’t be modified during revolution.
Whether select to use memory function of power failure or not.
Cd79=0 Disable auto saving
Cd79=1 Enable auto saving. When power off and current step PLC will be recorded
automatically.
§
Cd80
Modbus Protocol and communication mode setting (settable range 0-6)
This function can’t be modified during revolution.
Selection of operation method on RS485 communication port. Supporting Modbus
Protocol.