CE48
Multi steps function operation reset (settable range0~1)
The function cannot be modified during revolution
Memorized of current operation step and time (in sec) while shut down or power failure.
Step and time reset to 0 when set CE48=1.
Note: External terminal 6 set to RST function, when RST connect with COM, it will reset
the records and steps time to 0.
§
CE49
Multi steps process control continuous operation (settable range0~1)
The function cannot be modified during revolution
Selection of shut down or start from 1
st
step while entire operation procedure finished.
CE49=0 Not continuous operation.
CE49=1 Continuous operation. From 1st steps’ speed continuous operation.
CE49=2 Continuous operation, perform speed as the last speed in the step, till the
RST or CE48 set to1, then change to first step’s speed.
Not continuous
operation
F re q u e n c y
t
F irs t ste p
la s t s te p
Continuous
operation
freque ncy
t
From 1st step speed
continuous operation.
First step
last step
Continuous
operation, perform
speed as the last
speed in the step,
till the RST or CE48
set to1
fre qu ency
t
Pe rfo rm s pee d a s th e last spe ed in the step ,
till the R S T o r C E4 8 se t to 1 , then c han ge
to first ste p’s s peed to con tinuou s op eration
First ste p
Las t step