Setup extend temperature sensor
4.7.1
S
etup
extend
temperature
CWT501
6
can connect
4
extend wired temperature sensors DS18B20.
Y
ou can preset a high and a low level fo
r every channel, if the current temperature is above the high level
or below the low level, CWT5016 alarm.
You
can also send sms command to get current temperature.
DS18B20
temperature probes
temperature range:
-
55
~
+125
;
precision
±0.5
A
djustments
Y
ou
can set the value to reduce
error
.
Alarm
sms interval
T
he time is
designed
to avoid amounts of alarm/recover sms in a short time.
Re
-
alarm sms interval
Designed for repeat alarm status notifies
to phones, 0 means disable repeat notification.
Alarm ensuri
ng timer
It i
s
a counter of alarm status ensure timer, designed to avoid shake mistakes. 0 means no counter.
24 Hours
property
I
f checked,
the channel will execute alarm
action (
send alarm sms, interlock etc) when it is triggered,
even CWT5016 is in disa
rm status.
Sound
property
Means
this line alarm event will cause
internal
buzzer and extend buzzer or siren action.
“Enable”
property
E
nable
or disable this channel
s alarm
CWT501
6
Use
r
s manual
26
www.mobq2000.com
4.8
Others setting
4.8.1
Realtime
I
nterlock
R
ealtime interlock is a
local strategy
, it
is d
esigned to
outputs
automatically
execute action
under some
internal triggerin
g conditions.
F
or
example
If digital input 0 alert, output 0 close
pulse
5 seconds.