troubleSHootIng
ISSUE CAUSE SOLUTION
Unit doesn’t work aer
installation.
1. epowersourceisnotturnedON. 1. EnsurepowerisONforthecircuitbreakerand
unit.
2. epowerlineandthecablelockingconnector
arenotconnectedproperly.
2. Check the power connection with the unit is
connectedproperly.
3. eswitchbuttonseized. 3. Loosentheswitchmountingscrewsfromback
oftheswitch.
4. econtrolpanelandmotherboardwiringsare
disconnected.
4. Makesurewiringbetweenthecontrolpaneland
motherboardareconnectedproperly.
5. econtrolpanelormotherboardisdefective. 5. Change the control panel or motherboard
board.
Light indicates power
ON but motor doesn’t
turn.
1. emotorisdefective,possiblyseized. 1. Changethemotor.Servicingmayberequired.
2. eswitchbuttonseized.. 2. Loosentheswitchmountingscrewsfromback
oftheswitch.
3. econtrolpanelormotherboardisdefective. 3. Change defective part. Servicing may be
required.
e unit vibrates. 1. emotorisnotsecured. 1. Tightenthemotorinplace.
2. Damagedblowerwheel. 2. Replace the blower wheel. Servicing may be
required.
3. ehoodisnotsecuredinplace. 3. Checktheinstallationofthehood.
4. Ventingducttoosmallorblockageintheduct
openingorductwork.
4. Checktheventingductandthewallcaporroof
cap.
Motor works but lights
do not turn on.
1. Defectivehalogenbulb. 1. Changethehalogenbulb.
2. elightbulbisloose. 2. Tightenthelightbulb.
3. ewireconnectorforlightsisloose. 3. Callforassistance.
4. Defectivelighttransformer. 4. Changetransformer.Servicingmayberequired.
e hood is not venting
out properly.
1. ehoodmightbehangingtoohighfromthe
cooktop.
1. Adjustthe distancebetweenthe cooktopand
thebottomofthehoodwithin28”-36”above
therange.
2. Blockageintheductopeningorductwork. 2. Removealltheblockingfromtheductworkor
ductopening.
3. Usingthewrongsizeofducting. 3. Useatleast6”ductwork.
Foradditionalserviceinquiries,contactCycloneservicingdepartmentat1-888-293-5662orService@CycloneRangeHoods.com