8 FACTORY SETTINGS
The system leaves the factory with a series of preset parameters, which may be changed according to the
requirements of the plant and of the user. Each change of the settings is automatically saved in the memory.
The factory (or default) settings are summed up in the following table. You can make a note of the values modified for
your own installation in the “MEMO” column.
As indicated in the table, some default values may differ depending on the market for which the system
is intended.
If desired, it is possible to restore the default settings, proceeding as described in paragraph 8.1.
Factory settings
Menus
Function
Parameter Value (*)
MEMO
1-2
Language
English
1-3
Time format
24h
AM PM
1-4
Unit of
Measure
Head Unit m (metres)
ft (feet)
Flow Unit m3/h US GPM
Temperature Unit °C °F
1-5
Pump Limits
H max (head) MAX
Q max (flow) MAX
1-6
Screen Sleep Time 1:00 h
1-7
Password
value 0 (not active)
2
Set Points 1-4
type of setpoint Speed %
2
SET1
setpoint Q 5 m3/h
20 GPM
setpoint % 50%
duration ENDLESS
2
SET2
setpoint Q 12 m3/h
50 GPM
setpoint % 70%
duration ENDLESS
2
SET3
setpoint Q 18 m3/h
80 GPM
setpoint % 85%
duration ENDLESS
2
SET4
setpoint Q 25 m3/h
110 GPM
setpoint % 100%
duration ENDLESS
3
Set Points 5-8 type of setpoint Flow
3
SET5
setpoint Q 5 m3/h
20 GPM
setpoint % 50%
3
SET6
setpoint Q 12 m3/h
50 GPM
setpoint % 70%
3
SET7
setpoint Q 18 m3/h
80 GPM
setpoint % 85%
3
SET8
setpoint Q 25 m3/h
110 GPM
setpoint % 100%
4
Quick Clean
setpoint 100%
duration 10 min
7
Priming
function enabled
Max Priming Speed
100%