13
GB
I
SX1000 SX1500 SX2000
FUNZIONI E IMPOSTAZIONI
Funzioni di protezione
Tutti gli amplicatori della serie SX sono
equipaggiati con una serie di ecacissime
protezioni che consentono di operare sempre in
condizioni di massima sicurezza.
Sistema di raffreddamento e protezione termica
Un eciente sistema di rareddamento previene
qualsiasi inconveniente di natura termica. L’aria
entra dalle prese del pannello anteriore attraversa
l’intero apparato e deuisce dalle feritoie del
pannello posteriore. Uno speciale dispositivo
di controllo termico adatta in maniera continua
la velocità delle ventole in funzione della
temperatura rilevata tramite sensori situati sui
dissipatori. Questo tipo di controllo garantisce
che il usso d’aria sia sempre proporzionato
alle condizioni termiche, assicura una maggior
silenziosità delle ventole quando l’amplicatore
opera con segnali a basso livello e riduce
l’accumulo di polvere all’interno dell’apparato. In
condizioni termiche estreme le ventole forzano
un grandissimo volume d’aria.
Quando l’amplicatore funziona a pieno regime
per lungo tempo e la ventola va al massimo,
se questa condizione viene mantenuta a
lungo e la temperatura sale al di sopra dei
105°C, l’amplicatore andrà in protezione
da surriscaldamento. Sul pannello frontale si
accenderà la spia di protezione “PROT e non ci
sarà più segnale d’uscita. È sempre necessario
che l’utente impieghi l’amplicatore in maniera
corretta, non colleghi carichi inferiori a 2 Ohm e
lasci libero il usso dell’aria di rareddamento a
ventola. Fatto questo, non ci dovrebbero essere
motivi che blocchino il segnale d’uscita.
NOTA: è possibile ridurre la temperatura
riducendo il volume d’uscita.
FUNCTIONS AND SETTINGS
Reliablity protection function
All the models in the SX series are tted with a
series of extremely ecient protection, which
ensure they can always be used with the utmost
security.
Cooling system and thermal protection
A highly sophisticated cooling system prevents
any problems of thermal nature.
Four built-in fans, two internal two external,
create a cooling air ow: the front-to-rear ow-
through system takes in air through the vents on
the front panel, passes it through the entire unit
and feeds it out through the slits on the back.
A special thermal control device constantly varies
fan speed according to the temperature detected
by the sensors located on the heat sink. This type
of control ensures that airow always matches
temperature conditions, makes the fan quieter
when the amplier is running with low signals
and reduces the dust build-up inside the unit.
At high temperatures, the fan is able to drive a
very large amount of air.
When the amplier works at full load and the
fan runs at the highest speed, if this state is kept
for a long time, the amplier probably will go in
overheat” protection. This protection decreases
the output power: in fact, if the temperature
reaches the 95° C threshold, the TEMP LED
on the front panel will start lighting up whilst
the ampliers output will decrease of 10dB.
If the temperature doesn’t lower and keeps
on increasing reaching the 105°C, the PROT
protection LED lights up and you will not have
any signal on output. Users must always operate
the equipment correctly, not loading the amplier
with less than 2 Ohms and leave unobstructed
the air ow coming from the cooling system fan.
In these conditions, there are no reason for the
amplier to go in over-heat protection and the
sound should come out from all loudspeakers.
NOTE: its possible to reduce the temperature
reducing the output volume.