EasyManua.ls Logo

Daewoo RFS-26D1 Series - Precautions During Heavy Repair

Daewoo RFS-26D1 Series
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
1) Nitrogen only should be used when cleaning inside of cycle pipes
inside and sealing.
2) Check leakage with an electronic leakage tester.
3) Be sure to use a pipe cutter when cutting pipes.
4) Be careful not the water let intrude into the inside of the cycle.
Others.
1) Weld under nitrogen atmosphere in order to prevent oxidation
inside a pipe. (Nitrogen pressure : 0.1~0.2 kg/cm2.)
Nitrogen blowing
welding.
1) Be sure to replace dryer when repairing pipes
and injecting refrigerant.
Replacement of dryer.
Removal of retained
refrigerant.
1) Use special parts and tools for R-134a or R-600aUse of tools.
PrecautionsItems
9-2. Precautions During Heavy Repair
1) Remove retained refrigerant more than 5 minutes after turning off
a refrigerator. (If not, oil will leak inside.)
2) Remove retained refrigerant by cutting first high pressure side
(dryer part) with a nipper and then cut low pressure side.
(If the order is not observed, oil leak will happen.)

Table of Contents

Related product manuals