56
1) Nitrogen only should be used when cleaning inside of cycle pipes
inside and sealing.
2) Check leakage with an electronic leakage tester.
3) Be sure to use a pipe cutter when cutting pipes.
4) Be careful not the water let intrude into the inside of the cycle.
Others.
1) Weld under nitrogen atmosphere in order to prevent oxidation
inside a pipe. (Nitrogen pressure : 0.1~0.2 kg/cm2.)
Nitrogen blowing
welding.
1) Be sure to replace dryer when repairing pipes
and injecting refrigerant.
Replacement of dryer.
Removal of retained
refrigerant.
1) Use special parts and tools for R-134a or R-600aUse of tools.
PrecautionsItems
9-2. Precautions During Heavy Repair
1) Remove retained refrigerant more than 5 minutes after turning off
a refrigerator. (If not, oil will leak inside.)
2) Remove retained refrigerant by cutting first high pressure side
(dryer part) with a nipper and then cut low pressure side.
(If the order is not observed, oil leak will happen.)