EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
5-14
©
200423
Draining and filling
5
ΞΦ95 series
5. Check the oil level after having taken the test
drive. The oil level must reach the rim of the
level check/filler opening (A).
6. Fit the level check/filler plug (A), tightening it
to the specified torque, see "Technical data".
5.8 FILLING GREASE SUPPLY OF THE AUTOMATIC LUBRICATION SYSTEM
1. Remove the dust cover from the filler
coupling.
2. Connect the filler hose to the filler coupling.
Ensure that the filler hose is completely filled
with grease so that no air bubbles can get
into the system.
3. Fill the reservoir to the specified maximum
level.
Note:
When filling the reservoir, the air above the
follower piston will escape. This air will flow
down through an opening in the piston line
and escape from the pump through the right-
angled coupling. Normally a small amount of
grease will escape from this coupling during
venting.
4. Remove the filler hose from the filler
coupling.
C900331