EasyManua.ls Logo

Dahua D-PFS4226-24ET-240 - Configuring STP Port

Dahua D-PFS4226-24ET-240
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
page.
Figure 4-2 STP bridge settings
Step 2 Configure parameters.
Table 4-1 Description of the STP bridge settings
Parameter Description
STP Mode
Enable or disable ring network function.
When STP is enabled, the Switch cannot be managed through
iLinksView.
STP mode and link aggregation function are mutually exclusive. After
configuring link aggregation, STP mode cannot be enabled.
Bridge Priority Set bridge priority. The value ranges from 0 to 61440.
Hello Time
Set the period of root bridge sending BPDU. The time ranges from 1 s to 10
s.
Max Age Set the aging time of current BPDU. The time ranges from 6 s to 40 s.
Forward Delay
After setting topological change, the bridge maintains the time of snooping
and study state. The time ranges from 4 s to 30 s.
Step 3 Click
Save
.
5.1.3 Configuring STP Port
Step 1 Select
Device Management
>
Spanning Tree
>
STP Port Settings
on the
System Info
page.