Figure 6-40
Parameter
Note
COM 1, COM
2
According to actual connected port A, B and select serial.
Light Type
Select small or big lamp
Work Mode
Select work mode, include
ForbiddenNO always OFF.
AlwaysNO always ON.
DefaultAccording to time or brightness, auto turn ON or OFF.
Check Status
Select to check status of light.
Light
Brightness
Set NO light normal working brightness.
Light ArrMask
Set light no.
Note: Auto work mode only.
Auto Mode
According to time or brightness auto turn on/off light.
TimeSet NO period, independent config 7 days a week with 6 periods
per day.
BrightnessWhen current brightness is below preset value, enable NO
light. When current brightness is higher than preset value, disable NO
light.
Note: Auto work mode only.