User Manual of NVR2XXX(-P4-P8) Series NVR
123
9.2.4 Configuring SNMP
Purpose:
You can use SNMP protocol to get device status and parameters related information.
Steps:
1. Enter the Network Settings interface.
Menu >Configuration> Network
2. Select the SNMP tab to enter the SNMP Settings interface, as shown in Figure 9. 13.
Figure 9. 13 SNMP Settings Interface
3. Check the SNMP checkbox to enable this feature.
4. Configure the following SNMP settings:
Trap Address: IP Address of SNMP host.
Trap Port: Port of SNMP host.
5. Click Apply button to save and exit the interface.
Note: Before setting the SNMP, please download the SNMP software and manage to receive the device
information via SNMP port. By setting the Trap Address, the NVR is allowed to send the alarm event and
exception message to the surveillance center.
9.2.5 Configuring Remote Alarm Host
Purpose:
With a remote alarm host configured, the NVR will send the alarm event or exception message to the host when an
alarm is triggered. The remote alarm host must have the Network Video Surveillance software installed.
Steps:
1. Enter the Network Settings interface.
Menu >Configuration> Network
2. Select the More Settings tab to enter the More Settings interface, as shown in Figure 9. 14.
Figure 9. 14 More Settings Interface
3. Enter Alarm Host IP and Alarm Host Port in the text fields.

Table of Contents