8.4 RS485 Bus FAQ
Phenomenon
Possible Reasons
Solution
Speed dome
can run self-
diagnosis but
I cannot
control it.
Host address(baud rate) and
speed dome address(baud
rate) are not match;
Positive and negative end of
RS485 Bus are
misconnected;
Connection cable is loose
RS485 Bus connection are
cut off;
Modify host or speed dome setup
Switch RS485 positive end and
negative end
Fix connection cable firmly
Replace RS485 Bus.
I can control
the speed
dome but is
not smooth
RS485 Bus connection are
not good
One RS485 bus is off
The distance between host
and speed dome is too far
Parallel connected too much
speed domes.
Connect RS 485 Bus again
Replace RS485 Bus
Add terminal matching resistance
Add RS485 distributor.