SiUS121630EA Pump Down Operation
Trial Operation and Field Settings 203
1. Pump Down Operation
Pump Down
Operation
In order to protect the environment, be sure to conduct pump down operation when relocating or
disposing the unit.
1. Remove the valve caps from the liquid stop valve and the gas stop valve.
2. Carry out forced cooling operation.
3. After 5 ~ 10 minutes, close the liquid stop valve with a hexagonal wrench.
4. After 2 ~ 3 minutes, close the gas stop valve and stop the forced cooling operation.
Gas stop valve
Close
Liquid stop valve
Valve caps
Hexagonal wrench
(R14566)

Table of Contents

Other manuals for Daikin 4MXS36NMVJU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 4MXS36NMVJU and is the answer not in the manual?

Daikin 4MXS36NMVJU Specifications

General IconGeneral
Model4MXS36NMVJU
CategoryAir Conditioner
Heating Seasonal Performance Factor (HSPF)4.0
Number of Connectable Indoor Units4
Seasonal Energy Efficiency Ratio (SEER)6.0
RefrigerantR32
Indoor Units CompatibilityCompatible with various indoor units
Indoor Unit Dimensions (HxWxD)Varies by model
Indoor Unit WeightVaries depending on the connected indoor unit model
Operating Temperature (Cooling)-10 to 46 °C
Operating Temperature (Heating)-15 to 24 °C
TypeMulti-Split System

Related product manuals