SiUS121630EA CTXG, CTXS, FTXS, CDXS, FDXS, FVXS Series Functions
Functions and Control 49
CTXS, FTXS series
CDXS, FDXS, FVXS series
Refer to Temperature Control on page 39 for details.
2.6 NIGHT SET Mode
Outline When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Mode
keeps the airflow rate setting.
Details NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in cooling, or lowers it slightly in heating. This
prevents excessive cooling or heating to ensure comfortable sleeping conditions, and also
conserves electricity.
Cooling
Heating
Zone B
Zone A
OFF
ON
Zone C
2.0˚C (3.6˚F)
1.0˚C (1.8˚F)
0.5˚C (0.9˚F)
1.5˚C (2.7˚F)
2.0˚C (3.6˚F)
Room thermistor temperature – target temperature
(R24033)
Zone B
Zone A
OFF
ON
Zone C
1.5˚C (2.7˚F)
Room thermistor temperature – target temperature
0˚C (0˚F)
(R24034)
1.0˚C (1.8˚F)
(R23917)
Target temperature
+0.5˚C (+0.9˚F)
temperature shift
Operation stops
at the set hour
0.5˚C (0.9˚F)
1 hour
TIMER operation
NIGHT SET Mode ON
Target temperature
–2˚C (–3.6˚F)
temperature shift
1 hour
2˚C (3.6˚F)
(R23918)
TIMER operation
NIGHT SET Mode ON

Table of Contents

Other manuals for Daikin 4MXS36NMVJU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 4MXS36NMVJU and is the answer not in the manual?

Daikin 4MXS36NMVJU Specifications

General IconGeneral
Model4MXS36NMVJU
CategoryAir Conditioner
Heating Seasonal Performance Factor (HSPF)4.0
Number of Connectable Indoor Units4
Seasonal Energy Efficiency Ratio (SEER)6.0
RefrigerantR32
Indoor Units CompatibilityCompatible with various indoor units
Indoor Unit Dimensions (HxWxD)Varies by model
Indoor Unit WeightVaries depending on the connected indoor unit model
Operating Temperature (Cooling)-10 to 46 °C
Operating Temperature (Heating)-15 to 24 °C
TypeMulti-Split System

Related product manuals