SiUS121630EA CTXG, CTXS, FTXS, CDXS, FDXS, FVXS Series Functions
Functions and Control 63
2.14 Other Functions
2.14.1 Hot-Start Function
In order to prevent the cold air blast that normally occurs when heating operation starts, the
temperature of the indoor heat exchanger is detected, and the airflow is either stopped or
significantly weakened resulting in comfortable heating.
Note: The cold air blast is prevented using similar control when defrost control starts or when the
thermostat is turned ON.
2.14.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal receiving
sound and the operation lamp blinks.
2.14.3 Indoor Unit ON/OFF Button
ON/OFF button is provided on the display of the unit.
Press ON/OFF button once to start operation. Press once again to stop it.
ON/OFF button is useful when the remote controller is missing or the battery has run out.
In the case of multi system operation, there are times when the unit does not activate with this
button.
CTXG Series
Operation mode Temperature setting Airflow rate
AUTO 25°C (77°F) Automatic
CTXS/FTXS Series CDXS/FDXS Series
(R23923)
ON/OFF button
(R23924)
ON/OFF button
(R23925)
ON/OFF button

Table of Contents

Other manuals for Daikin 4MXS36NMVJU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 4MXS36NMVJU and is the answer not in the manual?

Daikin 4MXS36NMVJU Specifications

General IconGeneral
Model4MXS36NMVJU
CategoryAir Conditioner
Heating Seasonal Performance Factor (HSPF)4.0
Number of Connectable Indoor Units4
Seasonal Energy Efficiency Ratio (SEER)6.0
RefrigerantR32
Indoor Units CompatibilityCompatible with various indoor units
Indoor Unit Dimensions (HxWxD)Varies by model
Indoor Unit WeightVaries depending on the connected indoor unit model
Operating Temperature (Cooling)-10 to 46 °C
Operating Temperature (Heating)-15 to 24 °C
TypeMulti-Split System