3 Set-up and installation
Installation manual
13
Daikin Altherma ETS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1448499_00 – 06/2019 – EN
Minimum distance
DANGER: RISK OF BURNING
The plastic wall of the storage tank on the indoor unit can
melt under the effects of external heat (>80°C) and, in the
extreme case, can catch fire.
Only install the indoor unit at a minimum clearance of
1m from other heat sources (>80°C) (e.g. electrical
heater, oil heater, chimney) and combustible material.
CAUTION
If the indoor unit is not installed at a sufficient dis-
tance below the flat solar panels (the top edge of the stor-
age tank is higher than the bottom edge of the solar pan-
els), the unpressurised solar system in the outdoor area
will not be able to drain completely.
When a solar connection is used, install the indoor unit
low enough under the flat solar panels (observe the
minimum gradient of the solar connection lines).
Recommended minimum distances:
From the wall: (rear) ≥100mm, (sides) ≥500mm
From the ceiling: ≥1200mm, at least 480mm.
Distances from the outdoor unit:
When selecting the installation location, the data in the Tab. 3-2
must be taken into account.
Maximum line length between the indoor and out-
door units
50m
Maximum height difference between the indoor and
outdoor units
10m
Tab.3-2
3.3.2 Installing the device
WARNING
When unfilled, the indoor unit is top-heavy and could tip
over during transport. That could put persons in danger or
damage the unit.
Secure the indoor unit well, transport carefully, use the
handles.
Precondition
The installation site complies with applicable country-specific reg-
ulations and meets the minimum requirements described in
Chap. 3.3.1.
Installation
Fig.3-6 Installing the handles
A Handle
B Cover panel
F Threaded piece
1 Remove the packaging and dispose of it in an environment-
friendly manner.
2 Pull the cover screens off the storage tank (Fig. 3-6, itemB) and
unscrew the threaded fittings (Fig. 3-6, itemF) from the open-
ings at which the handles are to be fitted.
3 Screw the handles (Fig. 3-6, itemA) into the now uncovered
threaded holes.
4 Carefully transport the indoor unit to the installation site, use the
handles.
5 Install the indoor unit at the installation site.