3 Set-up and installation
Installation manual
17
Daikin Altherma ETS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1448499_00 – 06/2019 – EN
Fig.3-20 Heating inflow and return flow connections aligned to the
rear
10 Slide the retaining plate between the manifold and its horizontal
mounting and insert the manifold (Fig. 3-20, itemF) back into its
mounting through the middle hole of the retaining plate.
11 Secure the manifold with securing clip (Fig. 3-20, itemG) in its
mounting again.
12 Insert the two connection couplings (Fig. 3-20, itemB) into the
lateral mountings through the retaining plate.
13 Secure the two connection couplings with securing clips
(Fig. 3-20, itemC) in their mountings.
14 Insert the sealing plug (Fig. 3-20, itemE) into the upper mount-
ing.
15 Secure the sealing plug with securing clip (Fig. 3-20, itemD).
16 Cut out side openings in the thermal insulation (Fig. 3-21,
itemA) using a suitable tool.
Fig.3-21 Cut-out in thermal insulation
3.4.8 Making the hood opening
1 With the heating inflow and return flow directed upwards: Cut the
hood along the perforation with a suitable tool.
Fig.3-22 Making the hood opening
3.4.9 Installing the rotary switch of the
controller
1 Place the rotary switch on the rotary switch holder of the RoCon
+ HP and press it on.
Fig.3-23 Putting on the rotary switch
3.4.10 Securing the hood
After the installation is fully completed:
1 Attach the screws for fixing the hood (accessory bag).
Fig.3-24 Securing the hood
2 Place the front cover straight over the rotary switch of the RoCon
+ HP. Press on the top and bottom until the front screen is se-
curely engaged again.