4 About the units and options
Installer reference guide
10
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
EKMBUHCA3V3+9W1
Daikin Altherma low temperature monobloc
4P522034-1 – 2018.01
3.5.2 To remove the accessories from the
backup heater
1 Remove the wall bracket from the box.
4 About the units and options
4.1 Overview: About the units and
options
This chapter contains information about:
▪ Identifying the outdoor unit
▪ Identifying the control box (if applicable)
▪ Identifying the option box (if applicable)
▪ Identifying the backup heater (if applicable)
▪ Combining the outdoor unit with options
▪ Combining the control box with options
▪ Combining the option box with options
▪ Possible combinations of outdoor unit and domestic hot water tank
4.2 Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
4.2.1 Identification label: Outdoor unit
Location
Model identification
Example: EB/DLQ14CAV3
Code Explanation
E Monobloc outdoor heat pump
B
D
B=Reversible (heating+cooling)
D=Heating only
L Low water temperature – ambient zone: −10~
−25°C
Q Refrigerant R410A
14 Capacity class
CA Model series
V3 Power supply: 1~, 220~240 V, 50 Hz
W1 Power supply: 3N~, 380~415 V, 50 Hz
4.2.2 Identification label: Control box
Location
Model identification
Example: EKCB07 CA V3
Code Description
EK European kit
CB Control box
07 Capacity class
CA Model series
V3 Power supply
4.2.3 Identification label: Option box
Location
Model identification
Example: EK2CB07 CA V3
Code Description
EK European kit
2 Optional
CB Control box
07 Capacity class
CA Model series