ulse/kWh
A.2.2.F.5 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.F.6 [D-04] R/O
0: No
1: Yes
└─ Capacities
A.2.3.1 [6-02] R/W 0~10kW, step: 0,2kW
3kW
A.2.3.2 [6-03] R/W 0~10kW, step: 0,2kW
3kW
A.2.3.3 [6-04] R/W 0~10kW, step: 0,2kW
0kW
└─ Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.1.2.1 [9-01] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.1.2.2 [9-00] Temperature range Maximum temp (heating) R/W 37~55°C, step: 1°C
55°C
A.3.1.1.2.3 [9-03] Temperature range Minimum temp (cooling) R/W 5~18°C, step: 1°C
5°C
A.3.1.1.2.4 [9-02] Temperature range Maximum temp (cooling) R/W 18~22°C, step: 1°C
22°C
A.3.1.1.5 [8-05] R/W 0: No
1: Yes
A.3.1.1.7 [9-0B] R/W
0: Quick
1: Slow
└────────────────── Additional
A.3.1.2.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.2.2.1 [9-05] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.2.2.2 [9-06] Temperature range Maximum temp (heating) R/W 37~55°C, step: 1°C
55°C
A.3.1.2.2.3 [9-07] Temperature range Minimum temp (cooling) R/W 5~18°C, step: 1°C
5°C
A.3.1.2.2.4 [9-08] Temperature range Maximum temp (cooling) R/W 18~22°C, step: 1°C
22°C
Number of LWT zones
Pump operation mode
Power saving possible
User interface location
External sensor
Backup heater steps
BUH type
DHW pump
Glycol present
Preferential kWh rate
Contact type main
Ext. backup heat src
Alarm output
External kWh meter 1
External kWh meter 2
DHW operation
Contact type add.
External sensor
PCC by digital inputs
BUH: step 1
BUH: step 2
LWT setpoint mode
Modulated LWT
Booster heater
Emitter type
LWT setpoint mode