4 Operation
User reference guide
19
EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1A – 2016.02
Set weather-dependent heating/Set weather-dependent cooling
T
t
Target leaving water temperature
T
a
Outdoor temperature
a Low outdoor ambient temperature
b High outdoor ambient temperature
c Desired leaving water temperature when the outdoor
temperature equals or drops below the low ambient
temperature. Note: in heating, this value should be higher
than (d) as for low outdoor temperatures warmer water is
required. In cooling, this value should be higher than (d) as
for low outdoor temperatures less cold water suffices
d Desired leaving water temperature when the outdoor
temperature equals or rises above the high ambient
temperature. Note: in heating, this value should be lower
than (c) as for high outdoor temperatures less warm water
is required. In cooling, this value should be lower than (c)
as for high outdoor temperatures colder water is required.