5 Setting the energy prices
User reference guide
21
EHYHBH05AA + EHYHBH/X05+08AA + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1A – 2016.02
[7.6]
Units of measurement
Decimal point
Temperature
Pressure
Produced energy
[7.7]
Set weather dependent
Main
Additional
[7.7.1]
Main
Set weather-dependent heating
Set weather-dependent cooling
[7.7.2]
Additional
Set weather-dependent heating
Set weather-dependent cooling
Flow
Efficiency
Consumed gas
INFORMATION
Depending on the selected installer settings, settings will
be visible/invisible.
4.10 Installer settings: Tables to be
filled in by installer
4.10.1 Quick wizard
Setting Default Fill in…
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate 0 (No)
Space heating/cooling settings [A.2.1]
Unit control method 2 (RT control)
User interface location 1 (In room)
Number of LWT zones 0 (1 LWT zone)
Pump operation mode 2 (Request)
Domestic hot water settings [A.2.2]
DHW operation Depends on
model
DHW pump 0 (No)
Thermostats [A.2.2]
Contact type main 2 (H/C request)
Contact type add. 2 (H/C request)
External sensor 0 (No)
Digital I/O PCB [A.2.2.6]
Solar kit 0 (No)
Alarm output 0 (Normally open)
Demand PCB [A.2.2.7]
Demand PCB 0 (No)
Energy metering [A.2.2]
External kWh meter 1 0 (No)
Gas meter 0 (No)
4.10.2 Space heating/cooling control
Setting Default Fill in…
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode 1 (Weather dep.)
Leaving water temperature: Additional zone [A.3.1.2]
Setting Default Fill in…
LWT setpoint mode 0 (Fixed)
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT 1 (Yes)
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type 0 (Quick)
Savings mode [A.6.7]
Savings mode 0 (Economical)
Electricity price [7.4.5]
Elec price 20/kWh (High)
20/kWh (Medium)
15/kWh (Low)
Fuel price [7.4.6]
Fuel price 8.0/kWh
4.10.3 Domestic hot water control [A.4]
Setting Default Fill in…
Type 2 (Scheduled
only)
Maximum setpoint Depends on
model
INFORMATION
When the DHW tank booster mode is active, the risk of
space heating/cooling and capacity shortage comfort
problems is significant. In case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruptions will happen.
4.10.4 Contact/helpdesk number [6.3.2]
Setting Default Fill in…
Contact/helpdesk number —
5 Setting the energy prices
If your system's savings mode is set to Economical, it allows you to
set:
▪ a fixed gas price
▪ 3 electricity price levels