10 | Configuration
Installer reference guide
132
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
01
02
06
0a
0e
00 03
07
0b
0f
0000
04
08
0c
00 01
05
09
0d
15
Overview settings
Confirm
Adjust
Scroll
Result: The value to be modified is now highlighted.
4 Modify the value by using the and button.
01
02
06
0a
0e
00 03
07
0b
0f
0000
04
08
0c
00 01
05
09
0d
20
Overview settings
Confirm
Adjust
Scroll
5 Repeat previous steps if you have to modify other settings.
6 Push to confirm the modification of the parameter.
7 At installer settings menu, press to confirm the settings.
Installer settings
The system will restart.
Confirm Adjust
Cancel
OK
Result: The system will restart.
To copy the system settings from the first to the second user interface
If a second user interface is connected, the installer must first proceed below
instructions for the proper configuration of the 2 user interfaces.
This procedure offers you also the possibility to copy the language set from one
user interface to the other one: e.g. from EKRUCBL2 to EKRUCBL1.
1 Turn on the unit.
Result: When turned on for the first time, both user interfaces display:
15:10
Tue
U5:Auto address
Push 4 sec. to continue
2 Push for 4seconds on the user interface on which you want to proceed to
the quick wizard.
Result: This user interface is now the main user interface.
INFORMATION
While using the quick wizard on the main user interface, the second user interface
displays Busy and you cannot interact with it.