10 | Configuration
Installer reference guide
184
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
Parameter Setting Range Default
settings
Description
Minimal supply temperature
during OT demand.
(OpenTherm thermostat)
10°C~16°C 40°C Changing this setting has no
effect on the operation of the
unit.
. Reversible setting 0~1 1 This setting activates the keep
hot function of the gas boiler.
It is only used with reversible
heat pump models and should
NEVER be deactivated. It
MUST be deactivated for
heating only models (set to 0).
0=disabled
1=enabled
Start rpm space heating 50%~99% 50% This is the fan rpm before
heating ignition. It is
recommended not to modify
this setting.
. Start rpm domestic hot water
(not applicable for
Switzerland)
50%~99% 50% This is the fan rpm before
instant domestic hot water
ignition. It is recommended
not to modify this setting.
Maximum fan rpm 45~50 48 Use this parameter to set the
maximum fan rpm. It is
recommended not to modify
this setting.
Set point space heating (flow
temperature) during heating
external domestic hot water
tank
60°C~90°C 85°C Do NOT modify this setting on
the boiler. Use the user
interface instead.
. Comfort temperature 0°C / 40°C~65°C 0°C Temperature used for eco/
comfort function. When the
value is 0°C, the eco/comfort
temperature is the same as
the domestic hot water
setpoint. Otherwise, the eco/
comfort temperature is
between 40°C and 65°C.
. Waiting time after a space
heating demand from a
thermostat.
0min~15min 0min Changing this setting has no
effect on the operation of the
unit.
Waiting time after a domestic
hot water demand before a
space heating demand is
answered.
0min~15min 0min Amount of time the boiler
waits before answering a
space heating demand after a
domestic hot water demand.
. Number of eco days. 1~10 3 Number of eco days.