10 | Configuration
Installer reference guide
190
EPRA14~18DAV3+W1 + ETVH16SU18+23EA6V
Daikin Altherma 3 H HT F
4P644738-1 – 2021.02
T
DHW
Domestic hot water temperature
T
U
User setpoint temperature (as set on the user interface)
t Time
Example: setpoint (T
U
)≤maximum heat pump temperature–[6‑01] (T
HP MAX
–[6‑01])
t
[6-00]
HP
5
10
20
30
40
43
45
T
U
=T
HP OFF
T
HP MAX
T
DHW
T
HP ON
50
HP Heat pump. If heating up time by the heat pump takes too long, auxiliary heating by
the backup heater can take place
T
HP MAX
Maximum heat pump temperature at sensor in domestic hot water tank
T
HP OFF
Heat pump OFF temperature (T
HP MAX
−[6-01])
T
HP ON
Heat pump ON temperature (T
HP OFF
−[6-00])
T
DHW
Domestic hot water temperature
T
U
User setpoint temperature (as set on the user interface)
t Time
INFORMATION
The maximum heat pump temperature depends on the ambient temperature. For
more information, see the operation range.
WD curve type
There are 2 methods to define the weather-dependent curves:
2-points (see "10.4.22-points curve"[4150])
Slope-Offset (see "10.4.3Slope-offset curve"[4151])
In [2.E] WD curve type, you can choose which method you want to use.
In [5.E] WD curve type, the chosen method is shown read-only (same value as in
[2.E]).
# Code Description
[2.E] / [5.E] N/A 0: 2-points
1: Slope-Offset
10.5.7 User settings
Overview
The following items are listed in the submenu:
7
User settings
Information
Tank
Space heating/cooling
Installer settings
[7] User settings
[7.1] Language
[7.2] Time/date
[7.3] Holiday
[7.4] Quiet
[7.5] Electricity price
[7.6] Gas price