7 | Unit installation
Installer reference guide
74
EPRA14~18DAV3+W1 + ETVH16SU18+23EA6V
Daikin Altherma 3 H HT F
4P644738-1 – 2021.02
NOTICE
Level. Make sure the unit is level. Recommended:
Use 4 sets of M12 anchor bolts, nuts and washers. Provide at least 150mm of free
space below the unit. Additionally, make sure the unit is positioned at least
100mm above the maximum expected level of snow.
Anchor points
800
(mm)
479
Pedestal
When installing on a pedestal, make sure that the discharge grille still can be put in
its safety position. See "7.3.7To remove the discharge grille, and put the grille in
safety position"[478].
800
479
a
≥150
(mm)
M12
a Make sure not to cover the drain hole in the bottom plate of the unit.
7.3.4 To install the outdoor unit
1 Carry the unit by its slings, and put it onto the installation structure.