Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
9.I [6-09]
0
9.I [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
9.I [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.I [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.I [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
≠1
9.I [8-03] R/W 20~95 min, step: 5 min
50 min
9.I [8-04] R/W 0~95 min, step: 5 min
95 min
9.I [8-05] R/W
0: No
1: Yes
9.I [8-06] R/W 0~10°C, step: 1°C
5°C
9.I [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
9.I [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
9.I [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
9.I [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
9.I [8-0B]
13
9.I [8-0C]
10
9.I [8-0D]
16
9.I [9-00] R/W [2-0C]=2:
37~70, step: 1°C
70°C
37~68, step: 1°C (*7)
68°C
[2-0C]≠2:
37~55, step: 1°C
9.I [9-01] R/W 15~37°C, step: 1°C
25°C
9.I [9-02] R/W 18~22°C, step: 1°C
22°C
9.I [9-03] R/W 5~18°C, step: 1°C
7°C
9.I [9-04] R/W 1~4°C, step: 1°C
1°C
9.I [9-05] R/W 15~37°C, step: 1°C
25°C
9.I [9-06] R/W [2-0D]=2:
37~70, step: 1°C
70°C
37~68, step 1°C (*7)
68°C
[2-0D]≠2:
37~55, step: 1°C
9.I [9-07] R/W 5~18°C, step: 1°C
7°C
9.I [9-08] R/W 18~22°C, step: 1°C
22°C
9.I [9-09] R/W 1~18°C, step: 1°C
18°C
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
Anti-recycling time.
Booster heater delay timer.
Additional running time for the maximum running time.
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
--
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the desired DHW production type?
What is the maximum temperature setpoint?
Domestic hot water booster heater overshoot temperature.
Domestic hot water booster heater hysteresis.
How many leaving water temperature zones are there?
What is the allowed LWT undershoot during cooling start-up?
What is the desired eco main LWT in heating?
--
--
Maximum running time for domestic hot water operation.
What is the desired comfort main LWT in cooling?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
--
--
Boiler efficiency
Compressor forced OFF
BBR16 activation (#)
Minimum running time for domestic hot water operation.
--
Additional zone fixed pump PWM, in case a bizone kit is installed.
Main zone fixed pump PWM, in case a bizone kit is installed.
Time needed by the mixing valve to turn from one side to the other, in case a
bizone kit is installed.
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
4P644734-1 - 2021.02 (#) Only applicable in Swedish language.
(*1) *6V_(*2) *9W_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*_(*7) *SU*