1 STAGE STATUS CODES
39
Main
Menu
Option Menu
Active Alarm menu
xx
( xx: code numbers )
Last 6 Faults
F xx
( xx: code numbers )
Code Release Number
CR Number
Reset to Factory Default
F yes, no
Blower Speed for Continous Fan Mode
F Fxx
( xx: Blower Speed Number F01, F02.. )
Blower Speed for 1st Stage
Compressor Mode
Fxx
( xx: Blower Speed Number F01, F02.. )
Blower Speed for 2nd Stage
Compressor Mode
Fxx
( xx: Blower Speed Number F01, F02.. )
Cool On Delay

Delay, Seconds
Default set at 7 Secs, Adjustments can
be made in 7 Secs increments from 0 to
35 Secs
Cool Off Delay
Delay, Seconds
Default set at 65 Secs, Adjustments
can be made in 5 Secs increments from
0 to 120 Secs
Blower Speed for Gas Heat Mode
F Fxx
( xx: Blower Speed Number F01, F02.. )
Gas Heat On Delay

Delay, Seconds
Default set at 30 Secs, Adjustments
c
an be made in 5 Secs increments from
5 to 30 Secs
Gas heat Off Delay
F
Delay, Seconds
Default set at 90 Secs, Adjustments
can be made in 30 Secs increments from
30 to 180 Secs
Automatic Heat Staging - For Two
Stage Control
no, 10, 20, 30,
60, AUt
Refer to Section " CHANGING
HEATING MODE SETTING"
Menu Description
LED Display
Notes