SERVICING
37
STATIC PRESSURE DROP
If the total external static pressure and/or static pressure
drop exceeds the maximum or minimum allowable statics,

laid out duct work.
AIRFLOW CONSIDERATION
󰀨-
nicating system than in a non-communicating wired system.
The system operating mode (as determined by the thermo-
-
mand. If the indoor unit is responsible for determining the

ECM motor. If the outdoor unit or thermostat is responsible
for determining the demand, it calculates the demand and
transmits the demand along with a fan request to the indoor
unit. The indoor unit then sends the demand to the ECM
motor. The table below lists the various communication sys-

System
System Opera�ng
Mode
Airflow Demand
Source
Cooling Outdoor Unit
Heat Pump Hea�ng
Only
Outdoor Unit
Con�nuous Fan Thermostat
HP + Electric Heat
Strips
Either Outdoof Unit
or Indoor Unit,
which has higher
Airflow demand
Electric Heat Strips
Only
Indoor Unit
Gas Furnace Combus�on Heat Indoor Unit
Any
Air Handler or
Modular Blower
For example, assume the system is an outdoor unit matched
with an indoor unit. With a call for cooling, the outdoor unit
-
door unit will then send a fan request along with the cooling


         -
tinuous fan mode, the communicating thermostat provides
-
uous fan speeds (25%, 50%, 75% and 100% of maximum
      
sends a fan request along with the continuous fan demand
to the indoor unit. The indoor unit, in turn, sends the demand
to the ECM motor. The ECM motor delivers the requested
