SiUS041501E Field Settings
Trial Operation and Field Settings 106
3.2 When 2 Units are Installed in 1 Room
Outline When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different addresses.
Procedure (1) Remove the battery cover of the remote controller.
(2) Cut the address jumper.
(3) Press the center of the TEMP button and the OFF button on the remote controller at the same
time.
(4) Select
A
(address setting) with the TEMP or TEMP button.
(5) Press the FAN button to enter the address setting mode.
The indoor unit operation lamp blinks for 1 minute.
(6) Press the indoor unit ON/OFF button while the operation lamp is blinking.
(7) Press the FAN button on the remote controller for 5 seconds to return to the normal mode.
Address
EXIST
Jumper
CUT
1
2
(R21071)
Jumper
(R21822)
(R21072)
ON/OFF
OPERATION lamp
Indoor unit