EasyManua.ls Logo

Daikin FTK24NMVJU - Outdoor Unit

Daikin FTK24NMVJU
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wiring Diagrams SiUS041501E
119 Appendix
2.2 Outdoor Unit
RK(X)N09/12NMVJU, RK(X)09/12NMVJU
RKN18NMVJU
IPM1
X1M
DB1
L1R
MRM10
HR2
HL1
HR1
BLK
BRN
1L1
ORG
1
WHT
ZF
2
L2 2
HN1 V2
C400
RED
3
3
INDOOR
S
V3
L1
C405
MR30
V150
L2
GRN/YLW
UVW
SA1
E1
POWER SUPPLY
MRCW
PS
E2
S90S20 S40
GRN
FIELD WIRING.
61151
17
2
13
GRN
OUTDOOR
S71
S30
S80
PCB1
RED
RED
ORG
BLU
RED
BLK
BLK
BLU
ORG
BLK
BLK
RED
BLK
BLK
BRN
WHT
BLK
WHT
BLK
YLW
BLU
RED
YLW
Y1S
V
U
M
W
MS
Q1L
Y1E
M1F
M1C
Z1C
N=2
Z2C
N=2
Z3C
N=2
FU3
20A
~
~
FU2
3.15A
FU1
3.15A
MS
3
~
IN CASE OF
HEAT PUMP TYPE
NOTE
1. REFER TO THE NAME PLATE FOR THE POWER
REQUIREMENTS.
C400, C405
DB1
FU1, FU2, FU3
IPM1
L1, L2
L1R
M1C
M1F
MR30, MRM10, MRCW
PCB1
: CAPACITOR
: DIODE BRIDGE
: FUSE
: INTELLIGENT POWER MODULE
: LIVE
: REACTOR
: COMPRESSOR MOTOR
: FAN MOTOR
: MAGNETIC RELAY
: PRINTED CIRCUIT BOARD
PS
Q1L
R1T, R2T, R3T
S20, S30, S40,
S71, S80, S90
SA1
V2, V3, V150
: SWITCHING POWER SUPPLY
: OVERLOAD PROTECTOR
: THERMISTOR
: CONNECTOR
: SURGE ARRESTER
: VARISTOR
X1M
Y1E
Y1S
Z1C~Z3C
ZF
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: REVERSING SOLENOID VALVE COIL
: FERRITE CORE
: NOISE FILTER
: PROTECTIVE GROUND
R1T
(OUTDOOR)
R3T
(DISCHARGE)
R2T
(CONDENSER)
C: 3D089069
IPM1
X1M
DB1
L1R
MRM10
HR2
HL1
HR1
BLK BRN
1L1
ORG
1
WHT
ZF
2
L2 2
HN1
V2
C400
RED
3
3
INDOOR
S
V3
L1
C405
MR30
V150
L2
GRN/YLW
UVW
SA1
E1
POWER SUPPLY
MRCW
PS
E2
S90S20 S40
GRN
FIELD WIRING.
56111 71213
GRN
OUTDOOR
S71 S30S80
PCB1
RED
RED
BLU
RED
ORG
BLK
BLK
BLU
BLK
RED
BLK
ORG
BLK
BLK
BRN
WHT
BLK
WHT
BLK
YLW
BLU
RED
YLW
Y1S
V
U
M
W
MS
Q1L
Y1E
M1F
M1C
Z1C
N=4
Z2C
N=2
FU3
20A
Z3C
N=2
MS
3
~
IN CASE OF
HEAT PUMP TYPE
FU2
3.15A
NOTE
1.REFER TO THE NAMEPLATE FOR THE POWER
REQUIREMENTS.
C400, C405
DB1
FU1, FU2, FU3
IPM1
L1, L2
L1R
M1C
M1F
MR30, MRM10, MRCW
PCB1
: CAPACITOR
: DIODE BRIDGE
: FUSE
: INTELLIGENT POWER MODULE
: LIVE
: REACTOR
: COMPRESSOR MOTOR
: FAN MOTOR
: MAGNETIC RELAY
: PRINTED CIRCUIT BOARD
PS
Q1L
R1T, R2T, R3T
S20, S30, S40,
S71, S80, S90
SA1
V2, V3, V150
: SWITCHING POWER SUPPLY
: OVERLOAD PROTECTOR
: THERMISTOR
: CONNECTOR
: SURGE ARRESTER
: VARISTOR
X1M
Y1E
Y1S
Z1C~Z3C
ZF
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: REVERSING SOLENOID VALVE COIL
: FERRITE CORE
: NOISE FILTER
: PROTECTIVE GROUND
FU1
3.15A
R1T
(OUTDOOR)
R3T
(DISCHARGE)
R2T
(CONDENSER)
~
~
C: 3D091491

Table of Contents

Other manuals for Daikin FTK24NMVJU

Related product manuals