Main Functions SiUS041501E
25 Function and Control
1.3 Airflow Direction Control
Power-Airflow
Flap
The large flap sends a large volume of air downward to the floor and provides an optimum control in
cooling, dry, and heating operation.
<Cooling / Dry>
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown far
and distributed all over the room.
<Heating>
During heating operation, the large flap directs airflow downward to spread the warm air to the
entire room.
Wide-Angle
Louvers
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Auto-Swing The following table explains the auto-swing process for cooling, dry, heating, and fan:
COMFORT
AIRFLOW
Operation
The flap is controlled not to blow the air directly at the people in the room.
Flap (up and down)
Cooling / Dry Heating Fan
09/12 class
18/24 class
(R21048)
50˚
(R21049)
15˚
65˚
(R21050)
65˚
(R21651)
15˚
30˚
55˚
70˚
(R21652)
80˚
65˚
20˚
35˚
(R21653)
25˚
80˚
10˚
65˚
Cooling Heating
09/12 class
18/24 class
(R21186)
(R21187)
65˚
(R21861)
10˚