Specifications SiUS041501E
13 Specifications
60 Hz, 208 - 230V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Unit FTX09NMVJU FTX12NMVJU
Outdoor Unit
RX09NMVJU RX12NMVJU
Cooling Heating Cooling Heating
Capacity
Rated (Min. ~ Max.)
kW 2.64 (1.30 ~ 3.00) 2.93 (1.30 ~ 3.80) 3.20 (1.30 ~ 3.90) 3.96 (1.30 ~ 4.80)
Btu/h 9,000 (4,400 ~ 10,200) 10,000 (4,400 ~ 13,000) 10,900 (4,400 ~ 13,300) 13,500 (4,400 ~ 16,400)
kcal/h 2,270 (1,120 ~ 2,580) 2,520 (1,120 ~ 3,270) 2,750 (1,120 ~ 3,350) 3,410 (1,120 ~ 4,130)
Moisture Removal gal/h 0.32 0.45
Running Current (Rated) A 3.77 - 3.41 3.76 - 3.40 4.42 - 3.99 5.24 - 4.73
Power Consumption
Rated
(Min. ~ Max.)
W 721 (250 ~ 962) 722 (260 ~ 1,100) 874 (260 ~ 1,383) 1,041 (260 ~ 1,350)
Power Factor (Rated) % 91.9 - 91.9 92.3 - 92.3 95.1 - 95.2 95.5 - 95.7
COP Rated (Min. ~ Max.) W/W 3.66 (5.20 ~ 3.12) 4.06 (5.00 ~ 3.42) 3.66 (5.00 ~ 2.82) 3.80 (5.00 ~ 3.56)
EER Rated (Min. ~ Max.)
Btu/h·W
12.5 (17.6 ~ 10.6) 13.9 (16.9 ~ 11.7) 12.5 (16.9 ~ 9.6) 13.0 (16.9 ~ 12.1)
SEER / HSPF 19.0 9.0 19.0 9.0
Piping Connections
Liquid in. (mm) φ 1/4 (φ 6.4) φ 1/4 (φ 6.4)
Gas in. (mm) φ 3/8 (φ 9.5) φ 3/8 (φ 9.5)
Drain in. (mm) φ 5/8 (φ 16.0) φ 5/8 (φ 16.0)
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length ft (m) 65-5/8 (20) 65-5/8 (20)
Max. Interunit Height Difference ft (m) 49-1/4 (15) 49-1/4 (15)
Chargeless ft (m) 32-13/16 (10) 32-13/16 (10)
Amount of Additional Charge of
Refrigerant
oz/ft
(g/m)
0.21 (20) 0.21 (20)
Indoor Unit FTX09NMVJU FTX12NMVJU
Front Panel Color White White
Airflow Rate
H
m³/min
(cfm)
11.8 (417) 11.4 (403) 12.3 (434) 11.7 (413)
M 8.4 (297) 9.3 (328) 8.8 (311) 9.1 (321)
L 6.9 (244) 7.1 (251) 7.0 (247) 7.3 (258)
SL 4.0 (141) 6.1 (215) 4.1 (145) 6.2 (219)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 21 28
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.25 - 0.23 0.23 - 0.21 0.28 - 0.25 0.25 - 0.23
Power Consumption (Rated) W 28 - 28 25 - 25 31 - 31 28 - 28
Power Factor (Rated) % 53.8 - 52.9 52.3 - 51.8 53.2 - 53.9 53.8 - 52.9
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-1/4 × 30-5/16 × 8-3/4 (285 × 770 × 223) 11-1/4 × 30-5/16 × 8-3/4 (285 × 770 × 223)
Packaged Dimensions (H × W × D) in. (mm) 12 × 32-11/16 × 14-3/16 (305 × 831 × 360) 12 × 32-11/16 × 14-3/16 (305 × 831 × 360)
Weight Lbs (kg) 18 (8) 18 (8)
Gross Weight Lbs (kg) 24 (11) 25 (11)
Sound Pressure Level H / M / L / SL dB(A) 43 / 36 / 30 / 19 43 / 36 / 29 / 25 45 / 37 / 30 / 19 45 / 37 / 30 / 26
Outdoor Unit RX09NMVJU RX12NMVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AUXD 1YC23AUXD
Motor Output W 790 790
Refrigerant Oil
Type FVC50K FVC50K
Charge oz (L) 12.4 (0.375) 12.4 (0.375)
Refrigerant
Type R-410A R-410A
Charge Lbs (kg) 1.54 (0.70) 2.09 (0.95)
Airflow Rate
Hm³/min
(cfm)
31.2 (1,102) 28.5 (1,006) 31.3 (1,105) 26.1 (922)
SL 29.3 (1,035) 26.0 (918) 24.5 (865) 22.0 (777)
Fan
Type Propeller Propeller
Motor Output W 14 18
Running Current (Rated) A 3.52 - 3.18 3.53 - 3.19 4.14 - 3.74 4.99 - 4.50
Power Consumption (Rated) W 693 - 693 697 - 697 843 - 843 1,013 - 1,013
Power Factor (Rated) % 94.7 - 94.7 94.9 - 95.0 97.9 - 98.0 97.6 - 97.9
Starting Current A 3.77 5.24
Dimensions (H × W × D) in. (mm) 21-5/8 × 26-9/16 × 11-3/16 (550 × 675 × 284) 21-5/8 × 26-9/16 × 11-3/16 (550 × 675 × 284)
Packaged Dimensions (H × W × D) in. (mm) 24-3/4 × 32-11/16 × 16 (629 × 830 × 407) 24-3/4 × 32-11/16 × 16 (629 × 830 × 407)
Weight Lbs (kg) 55 (25) 60 (27)
Gross Weight Lbs (kg) 66 (30) 71 (32)
Sound Pressure Level H dB(A) 46 48 49 49
Drawing No. C: 3D093558 C: 3D093559A
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
Heating
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
Piping Length 25 ft (7.5 m)